Zero-Compromise Quality & Global ESD Compliance
Every product manufactured by Monveris is verified against ANSI/ESD S20.20-2021, IEC 61340-5-1, and ISO 9001:2015 standards in our calibrated quality assurance testing laboratories.
Our Quality Philosophy: Verified Electrical Performance
Static charges are invisible, and their damage is frequently detected only after products reach end customers. Monveris maintains a state-of-the-art testing laboratory to certify surface resistance, static decay time, and charge generation before dispatch.
Key Testing Capabilities & Protocols
- Surface Resistance & Resistivity Testing: Point-to-point (Rp-p) and resistance to ground (Rg) measurement using concentric ring and 5-lb weighted probe fixtures according to ANSI/ESD STM11.11.
- Static Decay Time Analysis: Charge plate monitoring measuring decay from ±1,000V to ±100V in less than 0.05 seconds under controlled 12% relative humidity.
- Tribocharging & Voltage Generation: Human body walking tests with real-time waveform recording per ANSI/ESD STM97.2 to guarantee peak voltage generation below 100V.
- Physical & Mechanical Durability: Tensile strength, heat resistance up to 250°C (solder splash), chemical exposure, and abrasion wear tests.
Certifications & Compliance
Our production facilities are ISO 9001:2015 and ISO 14001:2015 certified, with full RoHS and REACH compliance documentation provided for every product shipment.
Quality framework
Our Quality Approach
Monveris focuses on these parameters from product selection through supply to guarantee dependable performance on the factory floor.
Application-Focused Selection
We select products according to the actual requirement — ESD workstation, production floor, storage, PCB handling, or cleanroom environment.
Defined Specifications
Material composition, physical dimensions, electrical characteristics and intended operating environment are verified before dispatch.
ESD Performance Verification
Products are evaluated against surface resistance, resistance-to-ground, conductivity, charge dissipation and grounding continuity.
Supplier Quality Audits
Monveris works with established manufacturing partners holding ISO 9001:2015 certifications and accredited testing laboratories.
Technical Documentation
Available datasheets, test reports, specifications and supplier documentation provided for customer evaluation and approval.
Specification Consistency
For bulk and repeat requirements, we focus on maintaining agreed product specifications across successive supply batches.
Checkpoints
ESD quality checkpoints by category
Key testing criteria verified against product specifications and international standards.
| Product category | Key verification parameters | Applicable standard |
|---|---|---|
| ESD Mats & Flooring | Surface resistance (106 - 109 Ω), resistance-to-ground (R-G), point-to-point resistance, seamless installation grounding | ANSI/ESD S20.20, ESD STM7.1, IEC 61340-4-1 |
| Wrist Straps & Cords | Continuity, grounding connection, 1 MΩ (±1%) operator safety resistor, cord flex resistance (> 20,000 cycles) | ANSI/ESD S1.1, IEC 61340-5-1 |
| ESD Footwear & Slippers | Electrical volume resistance (106 - 108 Ω), floor contact dissipation, heel grounder strap continuity | ANSI/ESD STM9.1, ESD SP9.2, EN ISO 20347 |
| Garments & Gloves | Fabric conductive fiber grid (5mm), surface resistivity, particle shedding, seam continuity, wash durability | ANSI/ESD STM2.1, IEC 61340-5-1 |
| Ionizers & Static Eliminators | Ion balance offset voltage (< ±15V), discharge decay time (< 1.0 second), air velocity | ANSI/ESD STM3.1, IEC 61340-5-1 |
| ESD Packaging & Bags | Electrostatic discharge shielding energy (< 10 nJ), surface resistivity (inner/outer), puncture resistance | ANSI/ESD S541, MIL-PRF-81705D |
| ESD Test Equipment | Measurement accuracy (±5%), test voltage calibration (10V/100V), probe weight certification (5 lbs) | ISO/IEC 17025 calibrated |
ESD Mats & Flooring
Key verification parameters: Surface resistance (10^6 - 10^9 Ω), resistance-to-ground (R-G), point-to-point resistance, seamless installation grounding
ANSI/ESD S20.20, ESD STM7.1, IEC 61340-4-1
Wrist Straps & Cords
Key verification parameters: Continuity, grounding connection, 1 MΩ (±1%) operator safety resistor, cord flex resistance (> 20,000 cycles)
ANSI/ESD S1.1, IEC 61340-5-1
ESD Footwear & Slippers
Key verification parameters: Electrical volume resistance (10^6 - 10^8 Ω), floor contact dissipation, heel grounder strap continuity
ANSI/ESD STM9.1, ESD SP9.2, EN ISO 20347
Garments & Gloves
Key verification parameters: Fabric conductive fiber grid (5mm), surface resistivity, particle shedding, seam continuity, wash durability
ANSI/ESD STM2.1, IEC 61340-5-1
Ionizers & Static Eliminators
Key verification parameters: Ion balance offset voltage (< ±15V), discharge decay time (< 1.0 second), air velocity
ANSI/ESD STM3.1, IEC 61340-5-1
ESD Packaging & Bags
Key verification parameters: Electrostatic discharge shielding energy (< 10 nJ), surface resistivity (inner/outer), puncture resistance
ANSI/ESD S541, MIL-PRF-81705D
ESD Test Equipment
Key verification parameters: Measurement accuracy (±5%), test voltage calibration (10V/100V), probe weight certification (5 lbs)
ISO/IEC 17025 calibrated
Standards compliance
Standards Compliance & ESD Programmes
Monveris aligns its product specifications and quality checks with recognized international static-control standards including ANSI/ESD S20.20-2021, IEC 61340-5-1, and ISO 9001:2015.
Request technical documentation
Need supplier credentials, ISO certificates or technical datasheets for an evaluation or customer audit? Ask our desk for certificates and test reports.
How we verify
- Surface resistance testing conducted with calibrated high-megohmmeters and concentric ring probes.
- Static decay time certified to discharge from +/-1,000V to +/-100V within 0.05 seconds.
- Continuous resistance-to-ground tracking on all installed flooring and modular workbenches.
- Full lot traceability and certificate of conformance (CoC) shipped with every commercial order.